Select a PDU

No Model

PowerLok PDUs are built to order. Choose a category based on your delivery and feature requirements. For additional details refer to a product data sheet. Please note that shipping dates vary by quantity, outlined below:

Fast Response: 1-23 (3-5 days), 24+ (3-5 weeks)
Select: 12-100 (3-5 weeks), 100+ (Call for time)
Build: 48+ (8-10 weeks)

 

Select a PDU

No Model

PowerLok PDUs are built to order. Choose a category based on your delivery and feature requirements. For additional details refer to a product data sheet. Please note that shipping dates vary by quantity, outlined below:

Fast Response: 1-23 (3-5 days), 24+ (3-5 weeks)
Select: 12-100 (3-5 weeks), 100+ (Call for time)
Build: 48+ (8-10 weeks)

 

PDU Type
Voltage Series
Amperage
PDU Length
Results: Select model below to access product page
CarbonRedWhiteBlue
Receptacle Group 6 FT Whip 10 FT Whip 6 FT Whip 10 FT Whip 6 FT Whip 10 FT Whip 6 FT Whip 10 FT Whip
Receptacle Group 6 FT Whip 10 FT Whip Description
PDU Type
Voltage
Amperage
Plug Type
Whip Length (feet)
PDU Length (inches)
Receptacles
Color
CordLok
PDU Quantity
Minimum order quantity of 48 units applies
Build description
RACK PDU,
Additional Build Requirements

POWERLOK BUILD SPECIFICATION

Additional Build Requirements
Build SelectionsQuantity
DESCRIPTION
PDU TYPE
VOLTAGE
AMPERAGE
PLUG TPYE
WHIP LENGTH
PDU LENGTH
RECEPTACLES
COLOR
CORDLOK
Universal Specification
Over Current Protection20A UL489 magnetic breakers
Heavy Steel - Powder Coat ColorPer PowerLok specific configuration for color
Rack PDU TypeVertical Rack-mount
Manufactured in the USAYes
Product Warranty3-year from date of shipment, repair or replace.
Certification/Agency ApprovalsTUV Certified to UL/CSA 60950-1 with NOM Addendum for Mexico, FCC Part 15 Class A conformance, RoHS compliant
Operating Environment0-60C (32-149F), 5-95% relative humidity, 0-10,000ft (0-3000 meters) elevation.
Storage Environment-25-65C (-13-149F), 5-95% relative humidity, 0-10,000ft (0-3000 meters) elevation.
Monitored & Switched Versions Only
Monitoring TypeRemote & Touchscreen Display
Monitoring AccuracyVoltage: +/- 0.5% at nominal. Current: within 0.5% from 1A to 30A typical. +/1% of measurement from 500mA to 30A.
Total Unit & Group MonitoringAggregate (kWh, W, VA) plus Phase: A, B, C Line Currents, plus Group: 1, 2, 3 Monitoring (kWh, W, VA, PF, V, A)
Network InterfaceEthernet RJ-45, 10 Mbit/s, 100 Mbit/s
Transport/InternetTCP/IP v4, v6*
Network ApplicationsHTTP/HTTPS* Webserver
SNMP-V1/V2c/V3* Network Management
DHCP for dynamic IP address request from a server on the network.
Remote firmware upgrade using FTP.
Touch & Rotatable Digital DisplayTouch to rotate / touch to view data screens
Internal RMS Voltage SensorYes
Internal RMS Current SensorYes